Skip to content

Aluminium facade panel

Aluminium Facade Panel

2.0–3.0 mm solid aluminium cassettes with a 70% PVDF finish.

  • 2.0 / 2.5 / 3.0 mm
  • A2-s1,d0 fire class
  • ≤1.5 mm/m flatness
Close-up of a white facade screen with a repeating geometric panel pattern

Overview

How the system is built

BLTC manufactures and exports this system to facade contractors, developers and importers in North America, the Gulf and Europe. Solid aluminium panels are the workhorse of the rainscreen facade: 2.0–3.0 mm sheet, folded into a cassette with returns on all four sides, stiffened where the span demands it, and coated with 70% PVDF. They are used for spandrels, soffits, canopies, plant screens and complete ventilated facades where a flat, monolithic look is wanted.

The difference between a good and a poor panel is rarely the alloy — it is flatness after coating, the accuracy of the fold, and whether the stiffener pattern matches the wind load. We fold on CNC lines, check flatness on a granite bed, and pack with interleaving so panels arrive without handling marks.

Specifications

Aluminium Facade Panel data

Ranges we manufacture to. Project values are fixed by calculation and confirmed on the approved shop drawings.

Aluminium Facade Panel — technical data
Material AA3003-H14 or AA5005-H34 aluminium sheet
Thickness 2.0 mm, 2.5 mm, 3.0 mm
Surface finish PVDF 70% KYNAR 500, 2-, 3- or 4-coat, 25–35 µm; anodized 15–25 µm
Colour range RAL and NCS matches, metallic and mica options, wood-grain sublimation
Maximum panel size 1,500 × 4,000 mm flat; larger sizes on request
Fire rating A2-s1,d0 to EN 13501-1 (2.0 mm and above)
Flatness ≤1.5 mm per metre under standard viewing conditions
Weight 5.4–8.1 kg/m² depending on thickness
Fixing Secret-fix cassette, riveted tray or bonded to a carrier frame
Warranty 20 years on coating, project-specific

Panel size, stiffener pattern and fixing centres are set by wind-load calculation for each elevation. Soffit and canopy panels are usually specified one thickness up.

System details

Joints, movement and anchorage

The four details that decide whether the facade performs for twenty-five years. Project-specific drawings are issued for approval before production.

01

Cassette folding and stiffening

Returns are typically 20–25 mm, mitred and welded at the corners where a continuous edge is visible, or folded and riveted where it is not. Stiffeners are bonded or riveted to the rear face at centres calculated from the design wind pressure.

02

Sub-frame and ventilation

Cassettes are fixed to aluminium or steel sub-frame rails with concealed clips. The cavity behind is ventilated top and bottom and drained at the base, so the panel acts as a rainscreen rather than a sealed barrier.

03

Joints and tolerances

A 10–15 mm open joint is standard; a shadow-gap profile or gasket can close it if the design requires. Joint width is set on the setting-out drawing, not on site, so the grid reads correctly across a long elevation.

04

Edge and corner treatment

External corners are either a folded return on one panel or a dedicated corner extrusion. We recommend the extrusion where the corner is a focal point, because it keeps the two adjacent faces in one plane.

Finishes

PVDF or anodized?

Both are factory-applied and both last decades. The choice is usually decided by colour range and by what the specification in your market recognises.

Comparison of PVDF and anodized finishes
Property PVDF (70% KYNAR 500) Anodized
Film build 25–35 µm, 2- or 3-coat system15–25 µm, integral anodic layer
Colour range Full RAL / NCS range, metallics, mica, wood-grainNatural silver, champagne, bronze, black (limited)
Weathering AAMA 2605 / EN 12206, 10-year Florida exposureExcellent — the surface is not a coating
Colour stability ΔE ≤ 5 after 10 years, standard coloursNo coating to fade; colour is in the metal
Impact / abrasion Good; touch-up possible on siteVery good; scratches are difficult to repair
Best suited to Facades, panels, coastal and high-UV exposureInteriors, entrance frames, exposed metallic look
Warranty 20–30 years, project-specific10–15 years

Powder coating is available as a third option for interior and low-exposure applications. For coastal projects we default to a 3-coat PVDF build at 35 µm minimum.

Downloads

Documents for your submission

Open download centre

Files are released per project so that the correct profile family and revision reaches your consultant. Request the set and we will send it with the quotation.

Where it is used

Typical applications

FAQ

Questions about this system

If your question is about a specific elevation, send it with the drawing — the answer is usually in the geometry.

Solid panel or composite panel?
Solid aluminium is non-combustible, dimensionally stable and needs no core, which makes it the safer specification for high-rise and means no PE core to declare. Composite (ACP) is lighter and cheaper for large flat areas at low level, but its fire performance depends entirely on the core and it is increasingly restricted on tall buildings.
How flat will the panels be?
Flatness depends on thickness, panel size, stiffener pattern and colour — dark, glossy colours show every deviation. For panels over 1.2 m in the short direction we usually recommend 3.0 mm sheet and a bonded stiffener, and we will say so at quotation stage rather than after the mock-up.
Can you match an existing facade colour?
Yes. Send a physical sample or a RAL/NCS reference and we will match to a spray-out panel for approval. Metallic and mica colours are matched from the same pigment batch for the whole order to avoid batch-to-batch variation.

Aluminium Facade Panel

Send the elevation — we will price the package

Include the building height, the wind region and the glazing specification if you have it. We reply with a preliminary panel schedule, the applicable test reports and a quotation.